| Test Description | Results |
| Class | CW-PG50 |
| Water Penetration Resistance Test |
720Pa |
| Air Leakage Resistance Test |
Air leakage at +75 Pa:0.11L/s·m² Air leakage at -75 Pa:0.13L/s·m² |
| Uniform Load Deflection Test |
±2400Pa |
| U Factor Btu/Hr-Ft2-F) |
0.15 |
| Test Description | Results |
| Class | CW-PG40 |
| Water Penetration Resistance Test |
720Pa |
| Air Leakage Resistance Test |
Air leakage at +75 Pa:0.08L/s·m² Air leakage at -75 Pa:0.06L/s·m² |
| Uniform Load Deflection Test |
±1920Pa |
| U Factor Btu/Hr-Ft2-F) |
0.19 |

| Test Description | Results |
| Class | CW-PG40 |
| Water Penetration Resistance Test |
580Pa |
| Air Leakage Resistance Test |
Air leakage at +75 Pa:0.11L/s·m² Air leakage at -75 Pa:0.08L/s·m² |
| Uniform Load Deflection Test |
±1920Pa |
| U Factor Btu/Hr-Ft2-F) |
0.15 |

| Test Description | Results |
| Class | CW-PG40 |
| Water Penetration Resistance Test |
360Pa |
| Air Leakage Resistance Test |
Air leakage at +75 Pa:0.11L/s·m² Air leakage at -75 Pa:0.08L/s·m² |
| Uniform Load Deflection Test |
±1920Pa |
| U Factor Btu/Hr-Ft2-F) |
0.17 |